Categories
Price Range
Manufacturers
Themes
Home > Products > AC/DC Voltmeter Ammeter Temperature,Ohm meter > Elitech RC-4 USB Temperature Data Logger Recorder LCD ext sensor vs RC-4HC Humidity 16000 record Mini Size
Elitech RC-4 USB Temperature Data Logger Recorder LCD ext sensor vs RC-4HC Humidity 16000 record Mini Size
enlarge

Elitech RC-4 USB Temperature Data Logger Recorder LCD ext sensor vs RC-4HC Humidity 16000 record Mini Size

RM  159.00  119.00  
Item details
SKU: 1236 RC-4 S2
Weight: 200 grams
Stock: Stock available

Brand: Elitech
  Share This   Add To Facebook   Add To MySpace   
Product Overview
  • This data logger is mainly used for temperature recording during storage and transportation of foodstuff, medicine, chemicals and other products, especially widely used in all links of warehousing, logistics and cold chain, such as refrigerated containers, refrigerated trucks, refrigerated package, cold storage, laboratory, etc.
  • The data logger display interfaces includes: temperature status display, record capacity display, time display, date display, Max. temperature display, Min. temperature display
  • It has a large permanent data memory of 16000 points and comes with data management software for easy data download to computers through USB interface. With the software, you could analyze data in form of tables and graphs and export in picture format. The data could be queried, saved, printed and exported in Word/Excel/TXT format.
  • Data can be downloaded, analyzed, exported and printed conveniently 
 
Specification 
  • This model for Temperature data logger, if you need Temperature + Humidity, pls search "RC-4HC" in our store.
  • Product size: 84mm (length) X 44mm (width) X 20 mm (height)
     
    III.Technical parameters:
     
    1. Temperature unit:°C or °F optional
     
    2. Temperature measuring range:-30°C~+60°C;for optional external sensor, -40°C~+85°C;
     
    3.Ambient environmental temperature: -30°C~+60°C;
     
    4. Accuracy:+1°C;
     
    5. Resolution:0.1°C;
     
    6. Record capacity: 16000points(MAX);
     
    7. Record interval:10s~24hour adjustable;
     
    8. Sensor: Internal NTC thermal resistor;
     
    9. Communication interface:USB interface;
     
    10. Power supply:inner CR2450 battery or power supply via USB interface;
     
    11. Battery life: in normal temperature, if the record interval sets as 15 minutes, it could be used above one year.
     
    IV.Initial use:
     
    1. Install RC-4 temperature data logger data management software. Connect RC-4 with computer via USB, and install USB driver according to the Installation Tips.
     
    2. Open RC-4 temperature data logger data management software, after data logger connects with PC, it will upload information automatically. After checking the information, exit from connection interface.
     
    3. Click the parameters icon. After finish the parameters setting, click "save" button to save all the parameters and exit from parameter setting interface.
     
    4. Hold and press the button of data logger for above 4 seconds,the symbol“ ”will light, which means recording is started, then click “upload data” to check the data.
     
    5. Exit from RC-4 temperature data logger data management software.
     
    V.Data access
     
    The recorded data information could be accessed from the temperature data logger. And this process will not clear the historical memory or stop record process if it is in the record status. 
     
    1. Connect the data logger with computer via USB cable, after successfully connection, the icon shown in the LCD of data logger will light.
     
    2. Open RC-4 temperature data logger data management software, it will automatically upload the data log by default setting of software. It could cancel “Auto upload data” in the menu of “system setting”.
     
    3. After data uploading, you could check data table, curve graph and report, and export them in format of Word/Excel/PDF/TXT.Click the icon “save data” to save the data to the computer data base; click the icon “send mail” to send the data to the set mailboxes. For the details, please see “system mail setting”
     
    Note: RC-4 parameters setting is operated through computer, for the details, please see the help file of RC-4 temperature data logger data management software.
     
    VI.Function description
     
    The data logger display interfaces includes: status display, record capacity display, time display, date display, Max. temperature display, Min. temperature display, temperature upper limit display, temperature lower limit display.
     
    If no operation within 15 Seconds, the data logger will turn off the display automatically.
     
    If the display has been turned off, short press the button to enter the display interface. Each time press the button, it will shift among the display interfaces according to the sequence as described above. If the internal buzzer is selected, you could set the button warning tone in RC-4 temperature data logger data management software.
     
 
Included
  • 1*Temperature data logger(battery included);
  • 1*External Sensor;
  • 1*usb cable;
  • 1*CD driver;
  • 1*user manual;
Shipping & Warranty
  • Postage Method: 
  • Item usually will be post out same day / next working day (depends on Pos laju collection schedule) if payment verified before 12pm except there is special announcement.
  • Item usually will be arrive next working day after posted out for most of the major city area in West Malaysia, Sabah, Sarawak & Labuan
  • Parcel usually will be arrive within 1-3 working days EXCEPT: P.O.Box, rural area and unexpected delay by pos laju or missed delivery, addresee unreachable, etc.
  • 30 Days against manufacturer defect
About Us
  • Nobody is perfect, but we will try our best to serve your satisfaction and will improve from time to time. Your suggestion & understanding is highly appreciated.
  • Do not hesitate to contact us,  any enquiry, question, suggestion kindly email to us for faster reply at:
    • sales@ioline2u.com (Sales & After Sales Enquiry , Suggestion / Complaint )
    • support@ioline2u.com (Technical Support)

 


Last Updated @ 10/4/2015 3:06:57 PM